Packaged Pump Sets

High quality, fully packaged diesel driven ISOspec® pumpset.

Operating Limits

  • Flow to 450m³/hr
  • Maximum total head 160m
  • Liquid temperature 1 to 95°C
  • Operating pressure 16 Bar

Applications

  • Irrigation
  • Water supply
  • Dewatering

Features & Benefits

  • Driven via Yanmar Diesel engine, fully mounted on a purpose built, heavy duty steel skid base allowing easy
    on site installation.
  • Easy to view control panel and engine protection kit incorporating :-
    - Rev tachometer
    - Low oil pressure
    - High water temperature
    - Low radiator fluid level
    - 24 hour timer
    - Pump high/low liquid level switch - loss of prime
  • Manual variable engine speed controller providing total pump performance control.

Packaged water pressure system consisting of a Davey stainless steel vertical multistage pump with pressure tank, adjustable pressure switch, liquid filled pressure gauge, all mounted on a common base plate.

Operating Limits

  • Flow to 250lpm / 15m³/hr
  • Pressure heads to 98m
  • Maximum liquid temperature +70°C (tank)
  • Maximum ambient temperature +40°C

Applications

  • Household & commercial applications
  • Multi-dwelling water supply system
  • Turf watering & irrigation
  • Water supply, boosting & transfer
  • Water treatment

Features & Benefits

  • Davey vertical multistage centrifugal pump with superior hydraulic design. Powered by Davey's renowned Australian manufactured IP56 TEFC motor suitable for some of the most harsh conditions.
  • All hydraulic parts manufactured in stainless steel, providing corrosion protection.
  • Compact in-line suction & discharge for ease of installation.
  • Utilising the Davey Supercell range of captive diaphragm pressure tanks which feature a long lasting, bacteria resistant, crease free Butyl rubber diaphragm.
  • Completely assembled on a galvanised common Davey base plate for easy mounting.
  • Discharge manifold assembly in copper and brass, complete with isolation gate valve with an easy to read quality liquid filled pressure gauge.
  • Pressure adjustment is made simple with a fully adjustable pressure switch, providing a smooth on/off operation.

Monsoon 3C

Davey Monsoon packaged pump systems offer the choice and flexibility to best suit your application. An extensive choice of standard configurations is complimented by tailor made options. Monsoon systems can be supplied utilising V Series vertical multistage pumps, M Series horizontal multistage, Dynaflo, ISOspec® end suction centrifugal pumps, Davey Sump Pumps and even borehole submersible models. Flexibility of system design can allow the best combination of pumps to be chosen to ensure maximum operating range & high efficiencies are met, thereby reducing overall running costs. Davey Monsoon systems can be built to suit your needs from one pump up to six pumps. Monsoon systems can be operated via systems pressure, level or temperature. They can include constant speed controls or variable frequency drives. Monsoon systems are easy to operate, allowing full system status at the press of a button.

All Davey manifolding is manufactured using stainless steel as standard, providing high corrosion properties with options of either screwed or flanged connections. Monsoon systems are designed and assembled with the accreditation of IS09001, giving the peace of mind you have come to expect from an all Australian company that has pioneered pumping solutions since 1934.

  • System - Up to three pumps
  • Operation - Automatically controlled depending on system duty. Pumps can be automatically rotated to ensure equal operating hours for each pump.
  • Pumps - Up to three same or hydraulically similar pumps, maximum 110kW each pump

System includes

  • Microprocessor controlled pump system with electronic pressure sensing
  • All pumps operate on same pressure points to maximise performance from each pump
  • Easy access menus to enable adjustment to suit any operation
  • Adjustable parameters include cut-in pressure, cut-out pressure, low pressure cut-out, high pressure cut-out & minimum run timer
  • Status display includes system pressure, calculated flow rate, calculated total flow, hours run per pump, start meter per pump & system starts last hour
  • System protection includes low-pressure protection & high pressure protection with adjustable delay timer
  • Adjustable timer allows the system to be easily tuned to suit any pumping system
  • Selectable automatic or manual rotation of lead pump
  • Additional inputs include system pause, individual pump protection plus 8 additional, programmable inputs
  • System outputs include four configurable relays

Options

  • Individual pump protection, system no flow & system pause
  • Operation via switched inputs – floats, pressure switch
  • Level or temperature control mode

Monsoon 3V

System Operation

  • Monsoon 3V controller starts and stops pumps according to information collected from a pressure transducer and compares this to the reference set point. The controller maintains the system pressure at the set point by varying the speed of the VFD pump and switching other pumps ON and OFF. When the system detects NO flow it will shut down until the pressure drops below a restart point. The controller displays real pumping intelligence and offers very high running cost savings for variable flow reticulations.
  • Pumps Up to three same or hydraulically similar pumps, maximum 90kW each pump

System includes

  • Constant pressure control system with electronic pressure sensing
  • Easy access menus to enable adjustment to suit any operation
  • Adjustable parameters include cut-in pressure, set point, low pressure cut-out, high pressure cutout & minimum run timer
  • Status display includes system pressure, calculated flow rate, calculated total flow, hours run per pump, start meter per pump & system starts last hour
  • System protection includes low pressure protection & high pressure protection with adjustable delay timer
  • Adjustable timer allows the system to be easily tuned to suit any pumping system
  • Selectable automatic or manual rotation of lead pump
  • Additional inputs include system pause, individual pump protection plus 8 additional inputs
  • Four configurable output relays

Options

  • Individual pump protection, system no flow & system pause
  • Soft start manual back-up
  • Soft start lag pumps
  • Remote start / stop
  • 7 day time clock

Dual V36 Pump Set

CASCADING VFD
The Monsoon 3V cascade system starts the first pump via the VFD and continues to accelerate until the pump reaches full speed. If the system is not at the set point the controller then cycles the VFD to the next pump and switches the initial pump to full speed. This operation continues until the set point is reached or all pumps are running. The reverse occurs as the demand reduces. One VFD and bypass contactors are supplied for this option.
LEAD LAG
The Monsoon 3V lead lag system starts the first pump via the VFD and continues to accelerate until the pump reaches full speed. If the system is not at the set point the controller starts a LAG pump to make up for the flow demand. This is typically via a soft starter. This operation continues until the set point is reached or all pumps are running. The reverse occurs as the demand reduces. One VFD and one backup soft starter per lag pump are supplied for this option.
LEAD LAG AUTOROTATE
The Monsoon 3V lead lag auto rotate system starts the first pump via the VFD and continues to accelerate until the pump reaches full speed. If the system is not at the set point the controller starts a LAG pump to make up for the flow demand. This is typically via a soft starter. This operation continues until the set point is reached or all pumps are running. The reverse occurs as the demand reduces. This option varies from the Lead Lag by rotating the lead pump each time the system restarts. One VFD and one backup soft starter per pump are supplied for this option.
ALL VFD
The Monsoon 3V VFD per pump system starts the first pump via the VFD and continues to accelerate until the pump reaches full speed. If the system is not at the set point the controller then cycles the VFD to the next pump and switches the initial pump to full speed. This operation continues until the set point is reached or all pumps are running. The
reverse occurs as the demand reduces. One VFD per pump is supplied for this option.

© Steve Cselka 2002 - 2007